Split-Phase 240V Explained

Last updated: October 21, 2026

A North American home gets its power as split-phase: two 120 V “legs” that are 180 degrees out of phase with each other, plus a shared neutral. Each leg measures 120 V to the neutral, which feeds ordinary outlets and lights. Across the two legs you get 240 V, which feeds the big loads: electric dryers, ranges, water heaters, central air conditioning, well pumps and EV chargers.

A power station that puts out split-phase 120/240 V behaves like a small version of that panel. That is what lets it feed a home transfer switch or generator inlet and power both 120 V and 240 V circuits.

Three kinds of 240 V

The 240V ranking lists the first two kinds, then the paired ones separately.

What can it actually run?

The 240 V output shares the station’s single wattage limit (see watts, surge and boost mode). A station’s continuous wattage divided by 240 gives the current it can supply at 240 V. Big motor loads like central air and well pumps also need a high surge rating to start. Check the appliance’s nameplate and the station’s manual before you plan around it.

Connecting to a house

Feeding home circuits needs a properly installed transfer switch or interlock with a generator inlet, so the station can never push power back onto the utility lines. Have a licensed electrician install it. Never connect a station to a house through a dryer outlet or a double-ended cord.